澳洲燈具安全標準AS/NZS 60598.1新增修訂
2020年11月27日,澳洲官方發布了燈具安全標準的最新版本(主要修訂了澳洲偏差部分內容)AS/NZS 60598.1:2017+A1:2017+A2:2020。
The new amendment(A2:2020) is amended to the 2017 edition of AS/NZS 60598.1, and it is approved and published on 27 November 2020.
修訂主要在附錄ZZ的澳洲偏差:
The major revision is amended to appendix ZZ:
Clause |
修訂revision |
3.3.19 |
因澳大利亞/新西蘭不允許保護導體電流大于10mA,刪除 “允許說明書特別注明保護導體電流大于10mA”的要求。 Delete the text and replace with the following Note: |
3.3.103 |
墻壁安裝并自帶電源線插頭的燈具,電源線必須黏貼“警告:本燈具的外部軟線必須有效固定到墻壁”的警示標簽,以防止兒童被誤絞窒息及電擊危險。 After Clause 3.3.102, add new Clause 3.3.103, as follows:
|
4.32 |
刪除壓敏電阻的簡單要求,在4.32.3細化。 Appendix ZZ variation to Clause 4.32 |
4.32.1 |
增加防雷擊浪涌、瞬態過電壓保護裝置的分類,區分為SPD(浪涌保護裝置)和SPC(浪涌保護元件)。 Delete the text and replace with the following: |
4.32.2 |
SPD(浪涌保護裝置)需要符合IEC 61643-11標準。外置于控制裝置的SPD只能用于固定式燈具且必須連接到保護接地。 4.32.2 Surge protective devices (SPDs) |
4.32.3 |
外置于控制裝置的SPC(比如壓敏電阻、放電管等)需要滿足AS/NZS 3100的相關章節要求。 4.32.3 Surge protective components (SPCs) |
4.101 |
不再要求紐扣電池的電池腔蓋子只能借助工具才能打開。如果打開蓋子是通過兩個獨里的動作來完成的,亦可接受。 Appendix zz Clause 4.101 |
8.2.1 |
1、刪除最后一句描述,因為4.29章節已經有描述,無需贅述。 2、重新引入原來刪除的概念,但是修訂為“徒手可以移除的罩蓋需要先拿走”。 Appendix ZZ variations to Clause 8.2.1 |
10.2 |
新增電氣強度和絕緣電阻測試時需要先斷開的元器件種類(e)過電壓保護裝置和(f)滿足IEC 61347系列的控制裝置。 刪除第七段話,因為新增的(e)已經包含該內容。 Appendix ZZ variations to Clause 10.2 (new) Add the following after the variation to Clause 9.2: 10.2 1、Delete the fourth paragraph and replace with the following: During these tests, the following components shall be disconnected, so thatthe test voltages are applied to the insulation of the components, but not tothe capacitive, or inductive or other functional elements of these components,as appropriate: (a)Shunt-connected capacitors. (b)Capacitors between live parts and the body. (c)Protective impedance device. (d)Chokes or transformers connected between live parts. (e)Overvoltage protective devices in accordance with 4.32 of thisStandard, (f)Controlgear that conforms with the relevant requirements of IEC 61347series. 2、Delete the seventh paragraph which reads: For fixed Class 1 luminaires, overvoltage protective devices that comply withIEC 61643-11 shall be disconnected from the circuit |
13.3.3 |
新增豁免項,根據IEC 60695-11-10分類成V-0或V-1的材料,燈具使用時其厚度不小于材料認可時的厚度的,無需做針焰測試。 Add the following text to the end of fourth paragraph: The needle-flame test is not carried out on parts that are made of material classified as V-0or V-1 according to IEC 60695-11-10. The sample of material submitted to the test ofIEC 60695-11-10 shall be no thicker than the relevant part. |
建議產品制造商將新標準要求列入產品設計考量范圍,以備在未來半年內把產品認證標準升級為最新版!
LCS advise the manufacturers to design their product according the new requirement of standard, and update your certificate in the near future.